Инженерный калькулятор

Capacitor Energy and Peak Current Calculator

ВН+CVSRiIPKtЭто)

How to read the diagram. Closing the switch dumps the stored charge through the load resistor. Peak current is set by V / R at the instant of closure and then decays as e−t/RC, which is the pulse drawn on the right.

Stored energy decides whether a pulse is safe and whether the capacitor survives it. Enter capacitance, voltage and the discharge resistance to get energy, charge and peak current.

входные

Результаты

Накопленная энергия
-
Заряд
-
Пиковый ток
-
Постоянная времени
-

Формула

E = ½ × C × V². Charge Q = C × V. Peak discharge current I = V / R at the instant the circuit closes, decaying with τ = R × C.

What the calculator does not include

Выбор деталей

Pulse and PFN duty usually calls for N4700 Class 1 in a radial disc или screw-terminal doorknob. Class 2 drift makes those parts a poor fit for repeated pulses.

Send the calculated values and the duty: запросить техническое предложение, response within 6 hours.